AS/NZS 3010:2017 Electrical Installations Generating Sets
The Australian and New Zealand rules for connecting generators to electrical installations: siting and guarding, isolation for maintenance, MEN earthing, changeover devices that prevent back-feed, and extra rules for permanently connected and plug-in sets.
AS/NZS 3010:2017 Electrical Installations Generating Sets is a compliance framework from Australia and New Zealand with 5 domains and 50 controls that map to 1 other frameworks. The largest domains are Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (35 controls), Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (7 controls), Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets (6 controls). Every control below carries what it requires and what an assessor expects to see.
Framework summaries on this platform are AI-assisted interpretations for educational and compliance planning purposes. They do not reproduce or replace the official standards. Refer to the authoritative source for the definitive text. Framework names and trademarks belong to their respective organisations.
Framework Domains (5)
Appendices – AS/NZS 3010:2017 Electrical Installations Generating Sets
| Code | Title |
|---|---|
| as-nzs-3010-2017-electrical-installations-generating-sets::AppD | Appendix D: Construction and performance of self-contained transportable sets up to 25 kW |
Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets
| Code | Title |
|---|---|
| as-nzs-3010-2017-electrical-installations-generating-sets::2.1.3 | 2.1.3 Selection of generating set rating from load characteristics |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.1.4 | 2.1.4 Same system of supply whatever the source |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.10 | 2.10 Lightning protection of generating set installations |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.11-2.12 | 2.11 Sets as normal supply to a main switchboard and 2.12 sets connected as an alternative supply |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.2 | 2.2 Location of generating sets: exhaust, weather, hazardous areas and fuel fire risk |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.3.1 | 2.3.1 Protection from mechanical damage |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.3.2 | 2.3.2 Protection from moving parts |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.3.3 | 2.3.3 Protection against thermal effects above 120 C |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.3.4 | 2.3.4 Protection against fuel leakage |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.1 | 2.4.1 Control of the generating set |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.2 | 2.4.2 Prime mover isolating device to prevent starting during work |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.2.1 | 2.4.2.1 Operation of the prime mover isolating device |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.2.2 | 2.4.2.2 Location and securing of the isolating device |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.3 | 2.4.3 Synchronization with the network or other sets |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.4.4 | 2.4.4 Starting batteries and battery charging |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.5(a)-(c) | 2.5 Earthing arrangements (a) to (c): one MEN connection at the main switchboard |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.5(d)-(e) | 2.5 Earthing arrangements (d) and (e): no parallel neutral and earth; no electrode at the set |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.5(f)-(g) | 2.5 Earthing arrangements (f) and (g): changeover preserves installation functions; NZ main switchboard connection |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.1 | 2.6.1.1 Installation to AS/NZS 3000 and generator switchboards for multiple sets |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.2 | 2.6.1.2 Isolation from the normal supply system and approval for parallel running |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.3 | 2.6.1.3 Generator neutral treated as a live conductor |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.6.2 | 2.6.2 Overcurrent protection of outgoing circuits from the set |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.6.3 | 2.6.3 Generator output isolator switching all live conductors |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.1 | 2.7.1 Changeover devices for alternative (standby) supply and back-feed prevention |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.10 | 2.7.10 Changeover switching in the generator neutral (Australia and New Zealand rules) |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.11-2.7.13 | 2.7.11 to 2.7.13 Three-pole and four-pole changeover arrangements |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.2 | 2.7.2 Operation of changeover devices: break before make, active and neutral switching, no earth switching |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.3 | 2.7.3 Mechanical interlocking of changeover devices |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.4 | 2.7.4 Changeover device with intermediate off position used as a main switch |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.5 | 2.7.5 Changeover device without an off position: permitted connection points |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.6 | 2.7.6 Changeover device voltage, current and fault ratings |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.7-2.7.8 | 2.7.7 Access and 2.7.8 identification of changeover devices |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.7.9 | 2.7.9 Automatic changeover back to normal supply and ATS used as a main switch |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.8 | 2.8 Earthing and bonding of the generating set |
| as-nzs-3010-2017-electrical-installations-generating-sets::2.9 | 2.9 Generator switchboards and switchgear |
Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets
| Code | Title |
|---|---|
| as-nzs-3010-2017-electrical-installations-generating-sets::3.2-access | 3.2 Location: barriers against unauthorised access, access space and exits |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.2-environment | 3.2 Location: ventilation and lighting of generator rooms |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.3 | 3.3 Guarding of live parts |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.4 | 3.4 Transformers |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.5-changeover | 3.5 Sets supplying safety and essential services: changeover time and grouped switchgear |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.5-loads | 3.5 Sets supplying safety and essential services: selective protection, no unintended paralleling, other loads |
| as-nzs-3010-2017-electrical-installations-generating-sets::3.5-supply | 3.5 Sets supplying safety and essential services: capability, fuel, fire resistance and dedication |
Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets
| Code | Title |
|---|---|
| as-nzs-3010-2017-electrical-installations-generating-sets::4.2-other | 4.2.3 and 4.2.7 Other connection requirements for detachable connections |
| as-nzs-3010-2017-electrical-installations-generating-sets::4.2.4 | 4.2.4 Current limiting of each incoming generator supply |
| as-nzs-3010-2017-electrical-installations-generating-sets::4.2.5 | 4.2.5 Enclosure of live parts at the inlet and neutral pin isolation |
| as-nzs-3010-2017-electrical-installations-generating-sets::4.2.6 | 4.2.6 Marking of generator inlet fittings |
| as-nzs-3010-2017-electrical-installations-generating-sets::4.3 | 4.3 Earthing and bonding of sets on detachable connections; no separate electrode |
| as-nzs-3010-2017-electrical-installations-generating-sets::4.4 | 4.4 Connection of a portable set to a dedicated wiring system (New Zealand only) |
Status, scope and definitions – AS/NZS 3010:2017 Electrical Installations Generating Sets
| Code | Title |
|---|---|
| as-nzs-3010-2017-electrical-installations-generating-sets::1.2 | 1.2 Application: AS/NZS 3000 plus this Standard, with distributor and regulator requirements checked first |
Maps to 1 other framework
Coverage is not the same as your position
This page shows what AS/NZS 3010:2017 Electrical Installations Generating Sets overlaps with in general. Where your organisation actually stands, against the standard you are going for and the certifications you already hold, is a different question. Same graph and the same recorded refutations, scoped to you rather than to a pair.
The Compliance Position Diagnostic, $5,000 fixed, ten business daysWhat is AS/NZS 3010:2017 Electrical Installations Generating Sets and who does it apply to?
AS/NZS 3010:2017 Electrical Installations Generating Sets is a compliance framework from Australia and New Zealand with 5 domains and 50 controls. The Australian and New Zealand rules for connecting generators to electrical installations: siting and guarding, isolation for maintenance, MEN earthing, changeover devices that prevent back-feed, and extra rules for permanently connected and plug-in sets. It is used by organisations to establish and maintain compliance with industry standards and regulatory requirements.
What does AS/NZS 3010:2017 Electrical Installations Generating Sets actually require?
AS/NZS 3010:2017 Electrical Installations Generating Sets has 50 controls organised across 5 domains. The largest domains are Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (35 controls), Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (7 controls), Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets (6 controls). Each control defines specific requirements that organisations must implement to achieve compliance.
If I already comply with another framework, how much of AS/NZS 3010:2017 Electrical Installations Generating Sets do I already cover?
AS/NZS 3010:2017 Electrical Installations Generating Sets maps to 1 other compliance frameworks. The top mapping partners are NFPA 110-2025 Standard for Emergency and Standby Power Systems (44% coverage). Use our comparison tool to explore control-level mappings between frameworks.
How do I implement AS/NZS 3010:2017 Electrical Installations Generating Sets?
Start your AS/NZS 3010:2017 Electrical Installations Generating Sets compliance journey by running a self-assessment on our platform to identify your current compliance posture. Our AI advisory can answer specific questions about AS/NZS 3010:2017 Electrical Installations Generating Sets requirements, and cross-framework mapping helps you leverage existing controls from other frameworks you may already comply with. Create a free account to access all 50 controls and track your progress.