AS/NZS 3010:2017 Electrical Installations Generating Sets

Australia and New Zealand
vAS/NZS 3010:2017, second edition, published 8 May 2017, reissued incorporating Amendment No. 1 (published 24 April 2020)
5 domains
50 controls

The Australian and New Zealand rules for connecting generators to electrical installations: siting and guarding, isolation for maintenance, MEN earthing, changeover devices that prevent back-feed, and extra rules for permanently connected and plug-in sets.

Verified

AS/NZS 3010:2017 Electrical Installations Generating Sets is a compliance framework from Australia and New Zealand with 5 domains and 50 controls that map to 1 other frameworks. The largest domains are Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (35 controls), Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (7 controls), Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets (6 controls). Every control below carries what it requires and what an assessor expects to see.

Maintained by Gerard Blokdyk

Framework summaries on this platform are AI-assisted interpretations for educational and compliance planning purposes. They do not reproduce or replace the official standards. Refer to the authoritative source for the definitive text. Framework names and trademarks belong to their respective organisations.

Framework Domains (5)

Appendices – AS/NZS 3010:2017 Electrical Installations Generating Sets

1 controls
Controls in the Appendices – AS/NZS 3010:2017 Electrical Installations Generating Sets domain of AS/NZS 3010:2017 Electrical Installations Generating Sets — 1 controls
CodeTitle
as-nzs-3010-2017-electrical-installations-generating-sets::AppDAppendix D: Construction and performance of self-contained transportable sets up to 25 kW

Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets

35 controls
Controls in the Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets domain of AS/NZS 3010:2017 Electrical Installations Generating Sets — 35 controls
CodeTitle
as-nzs-3010-2017-electrical-installations-generating-sets::2.1.32.1.3 Selection of generating set rating from load characteristics
as-nzs-3010-2017-electrical-installations-generating-sets::2.1.42.1.4 Same system of supply whatever the source
as-nzs-3010-2017-electrical-installations-generating-sets::2.102.10 Lightning protection of generating set installations
as-nzs-3010-2017-electrical-installations-generating-sets::2.11-2.122.11 Sets as normal supply to a main switchboard and 2.12 sets connected as an alternative supply
as-nzs-3010-2017-electrical-installations-generating-sets::2.22.2 Location of generating sets: exhaust, weather, hazardous areas and fuel fire risk
as-nzs-3010-2017-electrical-installations-generating-sets::2.3.12.3.1 Protection from mechanical damage
as-nzs-3010-2017-electrical-installations-generating-sets::2.3.22.3.2 Protection from moving parts
as-nzs-3010-2017-electrical-installations-generating-sets::2.3.32.3.3 Protection against thermal effects above 120 C
as-nzs-3010-2017-electrical-installations-generating-sets::2.3.42.3.4 Protection against fuel leakage
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.12.4.1 Control of the generating set
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.22.4.2 Prime mover isolating device to prevent starting during work
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.2.12.4.2.1 Operation of the prime mover isolating device
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.2.22.4.2.2 Location and securing of the isolating device
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.32.4.3 Synchronization with the network or other sets
as-nzs-3010-2017-electrical-installations-generating-sets::2.4.42.4.4 Starting batteries and battery charging
as-nzs-3010-2017-electrical-installations-generating-sets::2.5(a)-(c)2.5 Earthing arrangements (a) to (c): one MEN connection at the main switchboard
as-nzs-3010-2017-electrical-installations-generating-sets::2.5(d)-(e)2.5 Earthing arrangements (d) and (e): no parallel neutral and earth; no electrode at the set
as-nzs-3010-2017-electrical-installations-generating-sets::2.5(f)-(g)2.5 Earthing arrangements (f) and (g): changeover preserves installation functions; NZ main switchboard connection
as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.12.6.1.1 Installation to AS/NZS 3000 and generator switchboards for multiple sets
as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.22.6.1.2 Isolation from the normal supply system and approval for parallel running
as-nzs-3010-2017-electrical-installations-generating-sets::2.6.1.32.6.1.3 Generator neutral treated as a live conductor
as-nzs-3010-2017-electrical-installations-generating-sets::2.6.22.6.2 Overcurrent protection of outgoing circuits from the set
as-nzs-3010-2017-electrical-installations-generating-sets::2.6.32.6.3 Generator output isolator switching all live conductors
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.12.7.1 Changeover devices for alternative (standby) supply and back-feed prevention
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.102.7.10 Changeover switching in the generator neutral (Australia and New Zealand rules)
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.11-2.7.132.7.11 to 2.7.13 Three-pole and four-pole changeover arrangements
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.22.7.2 Operation of changeover devices: break before make, active and neutral switching, no earth switching
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.32.7.3 Mechanical interlocking of changeover devices
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.42.7.4 Changeover device with intermediate off position used as a main switch
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.52.7.5 Changeover device without an off position: permitted connection points
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.62.7.6 Changeover device voltage, current and fault ratings
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.7-2.7.82.7.7 Access and 2.7.8 identification of changeover devices
as-nzs-3010-2017-electrical-installations-generating-sets::2.7.92.7.9 Automatic changeover back to normal supply and ATS used as a main switch
as-nzs-3010-2017-electrical-installations-generating-sets::2.82.8 Earthing and bonding of the generating set
as-nzs-3010-2017-electrical-installations-generating-sets::2.92.9 Generator switchboards and switchgear

Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets

7 controls
Controls in the Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets domain of AS/NZS 3010:2017 Electrical Installations Generating Sets — 7 controls
CodeTitle
as-nzs-3010-2017-electrical-installations-generating-sets::3.2-access3.2 Location: barriers against unauthorised access, access space and exits
as-nzs-3010-2017-electrical-installations-generating-sets::3.2-environment3.2 Location: ventilation and lighting of generator rooms
as-nzs-3010-2017-electrical-installations-generating-sets::3.33.3 Guarding of live parts
as-nzs-3010-2017-electrical-installations-generating-sets::3.43.4 Transformers
as-nzs-3010-2017-electrical-installations-generating-sets::3.5-changeover3.5 Sets supplying safety and essential services: changeover time and grouped switchgear
as-nzs-3010-2017-electrical-installations-generating-sets::3.5-loads3.5 Sets supplying safety and essential services: selective protection, no unintended paralleling, other loads
as-nzs-3010-2017-electrical-installations-generating-sets::3.5-supply3.5 Sets supplying safety and essential services: capability, fuel, fire resistance and dedication

Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets

6 controls
Controls in the Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets domain of AS/NZS 3010:2017 Electrical Installations Generating Sets — 6 controls
CodeTitle
as-nzs-3010-2017-electrical-installations-generating-sets::4.2-other4.2.3 and 4.2.7 Other connection requirements for detachable connections
as-nzs-3010-2017-electrical-installations-generating-sets::4.2.44.2.4 Current limiting of each incoming generator supply
as-nzs-3010-2017-electrical-installations-generating-sets::4.2.54.2.5 Enclosure of live parts at the inlet and neutral pin isolation
as-nzs-3010-2017-electrical-installations-generating-sets::4.2.64.2.6 Marking of generator inlet fittings
as-nzs-3010-2017-electrical-installations-generating-sets::4.34.3 Earthing and bonding of sets on detachable connections; no separate electrode
as-nzs-3010-2017-electrical-installations-generating-sets::4.44.4 Connection of a portable set to a dedicated wiring system (New Zealand only)

Status, scope and definitions – AS/NZS 3010:2017 Electrical Installations Generating Sets

1 controls
Controls in the Status, scope and definitions – AS/NZS 3010:2017 Electrical Installations Generating Sets domain of AS/NZS 3010:2017 Electrical Installations Generating Sets — 1 controls
CodeTitle
as-nzs-3010-2017-electrical-installations-generating-sets::1.21.2 Application: AS/NZS 3000 plus this Standard, with distributor and regulator requirements checked first

Maps to 1 other framework

50 total controls
NFPA 110-2025 Standard for Emergency and Standby Power Systems
22 source controls mapped|18 target controls covered
44%

Coverage is not the same as your position

This page shows what AS/NZS 3010:2017 Electrical Installations Generating Sets overlaps with in general. Where your organisation actually stands, against the standard you are going for and the certifications you already hold, is a different question. Same graph and the same recorded refutations, scoped to you rather than to a pair.

The Compliance Position Diagnostic, $5,000 fixed, ten business days

What is AS/NZS 3010:2017 Electrical Installations Generating Sets and who does it apply to?

AS/NZS 3010:2017 Electrical Installations Generating Sets is a compliance framework from Australia and New Zealand with 5 domains and 50 controls. The Australian and New Zealand rules for connecting generators to electrical installations: siting and guarding, isolation for maintenance, MEN earthing, changeover devices that prevent back-feed, and extra rules for permanently connected and plug-in sets. It is used by organisations to establish and maintain compliance with industry standards and regulatory requirements.

What does AS/NZS 3010:2017 Electrical Installations Generating Sets actually require?

AS/NZS 3010:2017 Electrical Installations Generating Sets has 50 controls organised across 5 domains. The largest domains are Section 2: General requirements for the installation of generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (35 controls), Section 3: Additional requirements for permanently connected generating sets – AS/NZS 3010:2017 Electrical Installations Generating Sets (7 controls), Section 4: Additional requirements for generating sets connected by detachable connections – AS/NZS 3010:2017 Electrical Installations Generating Sets (6 controls). Each control defines specific requirements that organisations must implement to achieve compliance.

If I already comply with another framework, how much of AS/NZS 3010:2017 Electrical Installations Generating Sets do I already cover?

AS/NZS 3010:2017 Electrical Installations Generating Sets maps to 1 other compliance frameworks. The top mapping partners are NFPA 110-2025 Standard for Emergency and Standby Power Systems (44% coverage). Use our comparison tool to explore control-level mappings between frameworks.

How do I implement AS/NZS 3010:2017 Electrical Installations Generating Sets?

Start your AS/NZS 3010:2017 Electrical Installations Generating Sets compliance journey by running a self-assessment on our platform to identify your current compliance posture. Our AI advisory can answer specific questions about AS/NZS 3010:2017 Electrical Installations Generating Sets requirements, and cross-framework mapping helps you leverage existing controls from other frameworks you may already comply with. Create a free account to access all 50 controls and track your progress.

Start Your Compliance Journey

Create a free account to run self-assessments, get AI advisory, and track your compliance progress across 868 frameworks.

Get Started Free →

Free forever — no credit card required