AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
The Australian and New Zealand Wiring Rules: the safety principles and deemed-to-comply installation practices for low voltage electrical installations, including RCD protection, switchboards, cable installation, earthing and bonding, bathrooms and pools, generators and solar, safety services and testing before energising.
AS/NZS 3000:2018 Electrical Installations (Wiring Rules) is a compliance framework from Australia and New Zealand with 8 domains and 66 controls. The largest domains are Part 1: Scope, application and fundamental principles (Section 1) – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (16 controls), Section 2: General arrangement, control and protection – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (12 controls), Section 4: Selection and installation of electrical equipment – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (12 controls). Every control below carries what it requires and what an assessor expects to see.
Framework summaries on this platform are AI-assisted interpretations for educational and compliance planning purposes. They do not reproduce or replace the official standards. Refer to the authoritative source for the definitive text. Framework names and trademarks belong to their respective organisations.
Framework Domains (8)
Part 1: Scope, application and fundamental principles (Section 1) – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.1 | 1.5.1 Protection against dangers and damage |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.11 | 1.5.11 Protection against abnormal voltages |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.12-1.5.14 | 1.5.12 to 1.5.14 Spread of fire, mechanical movement and external influences |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.2 | 1.5.2 Control and isolation |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.3-1.5.4 | 1.5.3 and 1.5.4 Protection against electric shock and basic protection |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.5 | 1.5.5 Fault protection |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.6 | 1.5.6 Additional protection by RCDs |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.7 | 1.5.7 Basic and fault protection by extra-low voltage |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.5.8-1.5.10 | 1.5.8 to 1.5.10 Thermal effects, overcurrent and earth fault currents |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.6 | 1.6 Design of an electrical installation |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.7.1-1.7.2 | 1.7.1 and 1.7.2 Selection and installation of equipment and work practice |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.7.3-1.7.4 | 1.7.3 and 1.7.4 Equipment selection and damp situations |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.8 | 1.8 Verification (inspection and testing) |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.9.1-1.9.2 | 1.9.1 and 1.9.2 Means of compliance: Part 2 and other standards |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.9.3 | 1.9.3 Alterations and repairs |
| as-nzs-3000-2018-electrical-installations-wiring-rules::1.9.4 | 1.9.4 Compliance by specific design and installation (Part 1 solution) |
Section 2: General arrangement, control and protection – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.10.2 | 2.10.2 Switchboard location, access and exits |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.10.3-2.10.7 | 2.10.3 to 2.10.7 Switchboard construction, bars, identification, wiring and fire protection |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.2 | 2.2 Arrangement of the installation: circuits and maximum demand |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.3 | 2.3 Control of the installation: isolation, main switches, emergency and functional switching |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.4 | 2.4 Fault protection |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.5 | 2.5 Protection against overcurrent and switchboard arcing faults |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.6.2 | 2.6.2 Selection of RCDs |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.6.3-alterations | 2.6.3.2.4 to 2.6.3.2.6 Home care, alterations, switchboard replacement and repairs |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.6.3-domestic | 2.6.3.2.2 RCDs in domestic and residential installations (Australia) |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.6.3-nondomestic | 2.6.3.2.3 RCDs in non-domestic installations (Australia) |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.7-2.8 | 2.7 and 2.8 Protection against overvoltage and undervoltage |
| as-nzs-3000-2018-electrical-installations-wiring-rules::2.9 | 2.9 Protection against fire hazard due to arcing faults (AFDDs) |
Section 3: Selection and installation of wiring systems – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.1-3.2 | 3.1 and 3.2 Wiring systems: general and types |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.10 | 3.10 Enclosure of cables |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.11 | 3.11 Underground wiring systems |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.12-3.13 | 3.12 and 3.13 Aerial wiring and catenary-supported cables |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.3 | 3.3 External influences on wiring systems |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.4-3.5 | 3.4 and 3.5 Current-carrying capacity and conductor size |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.6 | 3.6 Voltage drop |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.7 | 3.7 Electrical connections, joints and installation couplers |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.8 | 3.8 Identification of conductors |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.9 | 3.9 Installation requirements for wiring systems (other than mechanical protection) |
| as-nzs-3000-2018-electrical-installations-wiring-rules::3.9.4 | 3.9.4 Protection of wiring against mechanical damage |
Section 4: Selection and installation of electrical equipment – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.1 | 4.1 Electrical equipment: general, external influences and air extraction |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.12 | 4.12 Electricity converters (UPS, inverters) |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.13-4.17 | 4.13 to 4.17 Motors, transformers, capacitors, liquid dielectric equipment and batteries |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.18 | 4.18 Gas appliances and equipment |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.19-4.20 | 4.19 and 4.20 Air conditioning, heat pumps and lifts |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.2 | 4.2 Protection against thermal effects |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.3 | 4.3 Connection of electrical equipment |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.4 | 4.4 Socket-outlets |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.5 | 4.5 Lighting equipment, lampholders and recessed luminaires |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.6-4.7 | 4.6 and 4.7 Smoke alarms and cooking appliances |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.8 | 4.8 Appliances producing hot water or steam |
| as-nzs-3000-2018-electrical-installations-wiring-rules::4.9-4.11 | 4.9 to 4.11 Room heaters, heating cables and duct heaters |
Section 5: Earthing arrangements and earthing conductors – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::5.1-5.3 | 5.1 to 5.3 Earthing system: MEN, functions and parts |
| as-nzs-3000-2018-electrical-installations-wiring-rules::5.4-5.5 | 5.4 and 5.5 Earthing of equipment and earthing arrangements |
| as-nzs-3000-2018-electrical-installations-wiring-rules::5.6 | 5.6 Equipotential bonding |
| as-nzs-3000-2018-electrical-installations-wiring-rules::5.7-5.8 | 5.7 and 5.8 Earth fault-loop impedance and other earthing arrangements |
Section 6: Damp situations – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::6.2 | 6.2 Baths, showers and other fixed water containers |
| as-nzs-3000-2018-electrical-installations-wiring-rules::6.3-6.4 | 6.3 and 6.4 Swimming pools, spa pools and water features |
| as-nzs-3000-2018-electrical-installations-wiring-rules::6.5-6.7 | 6.5 to 6.7 Saunas, refrigeration rooms and hosing-down areas |
Section 7: Special electrical installations – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::7.2 | 7.2 Safety services |
| as-nzs-3000-2018-electrical-installations-wiring-rules::7.3 | 7.3 Electricity generation systems |
| as-nzs-3000-2018-electrical-installations-wiring-rules::7.4-7.5 | 7.4 and 7.5 Electrical separation and extra-low voltage installations |
| as-nzs-3000-2018-electrical-installations-wiring-rules::7.6-7.8 | 7.6 to 7.8 High voltage, hazardous areas and standards for specific installations |
| as-nzs-3000-2018-electrical-installations-wiring-rules::7.9 | 7.9 Supplies for electric vehicles (New Zealand only) |
Section 8: Verification – AS/NZS 3000:2018 Electrical Installations (Wiring Rules)
| Code | Title |
|---|---|
| as-nzs-3000-2018-electrical-installations-wiring-rules::8.1-8.2 | 8.1 and 8.2 Verification: general, periodic and visual inspection |
| as-nzs-3000-2018-electrical-installations-wiring-rules::8.3 | 8.3 Testing |
| as-nzs-3000-2018-electrical-installations-wiring-rules::8.4 | 8.4 Verification records |
What is AS/NZS 3000:2018 Electrical Installations (Wiring Rules) and who does it apply to?
AS/NZS 3000:2018 Electrical Installations (Wiring Rules) is a compliance framework from Australia and New Zealand with 8 domains and 66 controls. The Australian and New Zealand Wiring Rules: the safety principles and deemed-to-comply installation practices for low voltage electrical installations, including RCD protection, switchboards, cable installation, earthing and bonding, bathrooms and pools, generators and solar, safety services and testing before energising. It is used by organisations to establish and maintain compliance with industry standards and regulatory requirements.
What does AS/NZS 3000:2018 Electrical Installations (Wiring Rules) actually require?
AS/NZS 3000:2018 Electrical Installations (Wiring Rules) has 66 controls organised across 8 domains. The largest domains are Part 1: Scope, application and fundamental principles (Section 1) – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (16 controls), Section 2: General arrangement, control and protection – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (12 controls), Section 4: Selection and installation of electrical equipment – AS/NZS 3000:2018 Electrical Installations (Wiring Rules) (12 controls). Each control defines specific requirements that organisations must implement to achieve compliance.
If I already comply with another framework, how much of AS/NZS 3000:2018 Electrical Installations (Wiring Rules) do I already cover?
AS/NZS 3000:2018 Electrical Installations (Wiring Rules) does not currently have cross-framework mappings in our system. Check back as we continuously expand our mapping database.
How do I implement AS/NZS 3000:2018 Electrical Installations (Wiring Rules)?
Start your AS/NZS 3000:2018 Electrical Installations (Wiring Rules) compliance journey by running a self-assessment on our platform to identify your current compliance posture. Our AI advisory can answer specific questions about AS/NZS 3000:2018 Electrical Installations (Wiring Rules) requirements, and cross-framework mapping helps you leverage existing controls from other frameworks you may already comply with. Create a free account to access all 66 controls and track your progress.
Start Your Compliance Journey
Create a free account to run self-assessments, get AI advisory, and track your compliance progress across 849 frameworks.
Get Started Free →Free forever — no credit card required