ISO/IEC 27019:2024
SC 27's energy utility supplement to ISO/IEC 27002:2022: which controls apply unchanged, which carry guidance for process control systems, and the twelve ENR controls the standard adds for control centres, peripheral sites, legacy systems, safety functions, process control communication, external connections, least functionality and emergency communication. Thirteen leaves on the held preview and contents page; the body is not held and the leaves say so.
ISO/IEC 27019:2024 is a compliance framework from International (ISO/IEC JTC 1/SC 27) with 3 domains and 13 controls that map to 247 other frameworks. The largest domains are Clause 8: Technological controls for the energy utility industry – ISO/IEC 27019:2024 (6 controls), Clause 7: Physical controls for the energy utility industry – ISO/IEC 27019:2024 (4 controls), Clause 5: Organizational controls for the energy utility industry – ISO/IEC 27019:2024 (3 controls). Every control below carries what it requires and what an assessor expects to see.
Framework summaries on this platform are AI-assisted interpretations for educational and compliance planning purposes. They do not reproduce or replace the official standards. Refer to the authoritative source for the definitive text. Framework names and trademarks belong to their respective organisations.
Framework Domains (3)
Clause 5: Organizational controls for the energy utility industry – ISO/IEC 27019:2024
| Code | Title |
|---|---|
| iso-iec-27019-2024::5.2 | 5.2 Information security roles and responsibilities |
| iso-iec-27019-2024::5.38 | 5.38 ENR: Identification of risks related to external business partners |
| iso-iec-27019-2024::5.39 | 5.39 ENR: Addressing security when dealing with customers |
Clause 7: Physical controls for the energy utility industry – ISO/IEC 27019:2024
| Code | Title |
|---|---|
| iso-iec-27019-2024::7.15 | 7.15 ENR: Securing control centres |
| iso-iec-27019-2024::7.16 | 7.16 ENR: Securing equipment rooms |
| iso-iec-27019-2024::7.17 | 7.17 ENR: Securing peripheral sites |
| iso-iec-27019-2024::7.18 | 7.18 ENR: Interconnected control and communication systems |
Clause 8: Technological controls for the energy utility industry – ISO/IEC 27019:2024
| Code | Title |
|---|---|
| iso-iec-27019-2024::8.35 | 8.35 ENR: Treatment of legacy systems |
| iso-iec-27019-2024::8.36 | 8.36 ENR: Integrity and availability of safety functions |
| iso-iec-27019-2024::8.37 | 8.37 ENR: Securing process control data communication |
| iso-iec-27019-2024::8.38 | 8.38 ENR: Logical connection of external process control systems |
| iso-iec-27019-2024::8.39 | 8.39 ENR: Least functionality |
| iso-iec-27019-2024::8.40 | 8.40 ENR: Emergency communication |
Your Compliance Coverage
If you comply with ISO/IEC 27019:2024, you already cover:
API 1164
27%
16 controls mapped
Compare →IEC 62443
27%
16 controls mapped
Compare →NIST SP 1800-32
27%
16 controls mapped
Compare →+ 244 more: NIST SP 800-82 Revision 3: Guide to Industrial Control Systems (ICS) Security (25%), South Korea ISMS-P (22%)
See all 247 mapped frameworks ↓Maps to 247 other frameworks
Coverage is not the same as your position
This page shows what ISO/IEC 27019:2024 overlaps with in general. Where your organisation actually stands, against the standard you are going for and the certifications you already hold, is a different question. Same graph and the same recorded refutations, scoped to you rather than to a pair.
The Compliance Position Diagnostic, $5,000 fixed, ten business daysWhat is ISO/IEC 27019:2024 and who does it apply to?
ISO/IEC 27019:2024 is a compliance framework from International (ISO/IEC JTC 1/SC 27) with 3 domains and 13 controls. SC 27's energy utility supplement to ISO/IEC 27002:2022: which controls apply unchanged, which carry guidance for process control systems, and the twelve ENR controls the standard adds for control centres, peripheral sites, legacy systems, safety functions, process control communication, external connections, least functionality and emergency communication. Thirteen leaves on the held preview and contents page; the body is not held and the leaves say so. It is used by organisations to establish and maintain compliance with industry standards and regulatory requirements.
What does ISO/IEC 27019:2024 actually require?
ISO/IEC 27019:2024 has 13 controls organised across 3 domains. The largest domains are Clause 8: Technological controls for the energy utility industry – ISO/IEC 27019:2024 (6 controls), Clause 7: Physical controls for the energy utility industry – ISO/IEC 27019:2024 (4 controls), Clause 5: Organizational controls for the energy utility industry – ISO/IEC 27019:2024 (3 controls). Each control defines specific requirements that organisations must implement to achieve compliance.
If I already comply with another framework, how much of ISO/IEC 27019:2024 do I already cover?
ISO/IEC 27019:2024 maps to 247 other compliance frameworks. The top mapping partners are API 1164 (27% coverage), IEC 62443 (27% coverage), NIST SP 1800-32 (27% coverage). Use our comparison tool to explore control-level mappings between frameworks.
How do I implement ISO/IEC 27019:2024?
Start your ISO/IEC 27019:2024 compliance journey by running a self-assessment on our platform to identify your current compliance posture. Our AI advisory can answer specific questions about ISO/IEC 27019:2024 requirements, and cross-framework mapping helps you leverage existing controls from other frameworks you may already comply with. Create a free account to access all 13 controls and track your progress.
Start Your Compliance Journey
Create a free account to run self-assessments, get AI advisory, and track your compliance progress across 704 frameworks.
Get Started Free →Free forever — no credit card required