Australia National Construction Code 2022 Volume Two (Building Code of Australia, Class 1 and 10 Buildings)
Schedules 4 to 11: State and Territory variations and additions – Australia National Construction Code 2022 Volume Two (Building Code of Australia, Class 1 and 10 Buildings)

Australia National Construction Code 2022 Volume Two (Building Code of Australia, Class 1 and 10 Buildings) SA-OTHER: South Australia: brush fences, wet area floors, bushfire attack levels and flood provisions

South Australia varies H3P1(1) so that protection of a Class 1 building against fire spread covers fire from another building (other than its associated Class 10 building), from the allotment boundary (other than a road or public space boundary) and from a Class 10b brush fence. SA H4P1(2) requires floors of bathrooms and rooms with a shower or sanitary fixture to be installed so water does not accumulate on the surface. SA H7D4(3) fixes the bushfire attack level from the Planning and Design Code: BAL-Low in general bushfire risk areas, BAL-12.5 in medium risk areas, the AS 3959 site assessment in high risk areas, BAL-Low in urban interface areas within 500 m of a high risk area and the AS 3959 assessment within 100 m of one. SA H1P2 (buildings in flood areas) is left blank.

Maintained by Gerard Blokdyk

Other controls in Schedules 4 to 11: State and Territory variations and additions – Australia National Construction Code 2022 Volume Two (Building Code of Australia, Class 1 and 10 Buildings)

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.