Australia Disability Standards for Accessible Public Transport 2002
Parts 8 and 9 Boarding and allocated space: boarding points, boarding devices, removeable gangways, request signals, loading zones, taxi ranks, parking, allocated spaces – Australia Disability Standards for Accessible Public Transport 2002

Australia Disability Standards for Accessible Public Transport 2002 8.6C: Removeable gangways on ferries: long enough to keep safe clearance over the tidal and freeboard range and mechanically secured both sides; continuous handrails on both sides at least 1000 mm high and 800 mm apart with 30% luminance contrast and domed warning indicators at interruptions; upper and intermediate side barriers on stanchions no more than 2150 mm apart, with 65 to 75 mm edge barriers where the gap below the lowest rail exceeds 230 mm; direct assistance where any part exceeds 1:8; slip-resistant surface with a 50 to 75 mm contrasting leading-edge strip; designed and tested to 5.5 kPa and a 5000 N point load and proven by a practical boarding trial

What does 8.6C require?

A removeable gangway between a pontoon and a ferry deck must, across the normal range of tide and freeboard, be long enough to keep its entry and exit points a safe clearance from the quay or pontoon edge and the deck, and have an effective means of mechanically securing both sides. It must carry continuous handrails on both sides at least 1000 mm above the walking surface and at least 800 mm apart (wider where safe and practicable), complying with clause 9(b) of AS 1428.1 (2021), with a consistent finish, 30% luminance contrast wet and dry against the surface and fixed surfaces within 2 m, and a domed warning indicator 4 to 5 mm high and 10 to 12 mm across placed 150 mm before any interruption. Each side must be fenced its full length with upper and intermediate rails, taut ropes or chains or nylon barrier on lockable stanchions no more than 2150 mm apart, with no clear gap over 600 mm between handrail and intermediate rail, toe boards at least 60 mm high where the gap under the lowest rail exceeds 230 mm, and in that case continuous contrasting edge barriers 65 to 75 mm high with at least 800 mm clear between them. Where any part of the walking surface exceeds 1:8 direct assistance must be available. The surface must be slip resistant to clause 4.1 of AS 1428.1 (2021) with a solid contrasting strip 50 to 75 mm wide on the leading edges and any articulation gaps within clause 4.2 of that standard. The gangway must be designed, built and load tested to 5.5 kPa and a 5000 N concentrated load without failure or permanent deformation, and proven safe by a practical trial of boarding and disembarkation across the ferry's likely operating variances.

Maintained by Gerard Blokdyk

Other controls in Parts 8 and 9 Boarding and allocated space: boarding points, boarding devices, removeable gangways, request signals, loading zones, taxi ranks, parking, allocated spaces – Australia Disability Standards for Accessible Public Transport 2002

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.