The PCBU eliminates, or if not reasonably practicable minimises, the risk from substances or conditions introduced by connected plant or services and from their activation or energising (isolation and lockout); ensures purging or ventilation of contaminants so far as reasonably practicable without using pure oxygen or oxygen-enriched mixtures above 21%; ensures a safe oxygen level while work continues or, where that is not reasonably practicable and oxygen is below 19.5%, provides air-supplied respiratory equipment; keeps flammable gas, vapour or mist below 5% of the lower explosive limit so far as reasonably practicable, removing workers immediately at 5% to under 10% unless a calibrated continuous-monitoring detector is used, and at 10% or more in all cases; and prevents any ignition source being introduced where it could cause fire or explosion.