Where toilets are provided in premises or infrastructure there must be at least one unisex accessible toilet without airlock complying with section 12 of AS 1428.1 (2021), located with the other toilets. Where toilets are provided on a ferry or an accessible rail car there must be at least one unisex accessible toilet without airlock available to passengers using wheelchairs or mobility aids, and where two or more are provided there must be as near as possible equal numbers with the mobility aid space to the left and to the right of the pan. Such a toilet must let a passenger enter, position the aid and leave, and on new conveyances must have 450 mm from the pan centre line to the near wall, between 1150 and 1450 mm to the far wall, 800 mm from the back wall to the front of the pan, a seat 460 to 480 mm above the floor and hand washing inside the cubicle to clause 15.2.10 of AS 1428.1 (2009). On wide-body twin-aisle aircraft at least one toilet must be usable by a passenger with an on-board wheelchair, with direct assistance to the door. Where a coach toilet is not accessible the operator must offer stops at reasonable frequency at premises with accessible toilets.
The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.