Australia Disability Standards for Accessible Public Transport 2002
Parts 10 to 15 Built elements: surfaces, handrails and grabrails, doorways and doors, lifts, stairs and escalators, toilets – Australia Disability Standards for Accessible Public Transport 2002

Australia Disability Standards for Accessible Public Transport 2002 15: Toilets: where toilets are provided in premises or infrastructure at least one unisex accessible toilet without airlock to section 12 of AS 1428.1 (2021), co-located with other toilets; on ferries and accessible rail cars an accessible toilet a wheelchair user can enter, position in and leave, with 450 mm from pan centre to the near wall, 1150 to 1450 mm to the far wall, 800 mm from back wall to pan front, a 460 to 480 mm seat height and a basin inside the cubicle, and left and right handed layouts balanced where two or more are provided; wide-body aircraft with a toilet usable from an on-board wheelchair with direct assistance to the door; coaches offering stops at accessible toilets where the on-board toilet is not accessible

What does 15 require?

Where toilets are provided in premises or infrastructure there must be at least one unisex accessible toilet without airlock complying with section 12 of AS 1428.1 (2021), located with the other toilets. Where toilets are provided on a ferry or an accessible rail car there must be at least one unisex accessible toilet without airlock available to passengers using wheelchairs or mobility aids, and where two or more are provided there must be as near as possible equal numbers with the mobility aid space to the left and to the right of the pan. Such a toilet must let a passenger enter, position the aid and leave, and on new conveyances must have 450 mm from the pan centre line to the near wall, between 1150 and 1450 mm to the far wall, 800 mm from the back wall to the front of the pan, a seat 460 to 480 mm above the floor and hand washing inside the cubicle to clause 15.2.10 of AS 1428.1 (2009). On wide-body twin-aisle aircraft at least one toilet must be usable by a passenger with an on-board wheelchair, with direct assistance to the door. Where a coach toilet is not accessible the operator must offer stops at reasonable frequency at premises with accessible toilets.

Maintained by Gerard Blokdyk

Other controls in Parts 10 to 15 Built elements: surfaces, handrails and grabrails, doorways and doors, lifts, stairs and escalators, toilets – Australia Disability Standards for Accessible Public Transport 2002

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.