AS 3740:2021 Waterproofing of Domestic Wet Areas
Section 4: Installation - substrates, drainage connections and membranes – AS 3740:2021 Waterproofing of Domestic Wet Areas

AS 3740:2021 Waterproofing of Domestic Wet Areas 4.3.1: 4.3.1 Membrane to drainage connection at leak control flanges

The membrane is bonded onto the leak control flange and terminated horizontally, or horizontally and vertically. The flange is recessed into the substrate without protruding, sealed to the riser, fixed so it cannot move, of the same nominal diameter as the riser, and finished with a fillet of sealant where it meets the substrate. With a shower tray, the tile bed must be able to drain and the drain connection must be waterproof. The flange must not sit where it interferes with bond breakers or wall to floor junctions.

Maintained by Gerard Blokdyk

Other controls in Section 4: Installation - substrates, drainage connections and membranes – AS 3740:2021 Waterproofing of Domestic Wet Areas

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.