AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work
Section 10: Doorways, doors and circulation space at doorways – AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work

AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work 10.2: 10.2 Clear opening of doorways

Doorways on the path must give a clear opening of at least 850 mm, measured between the open door's face and the doorstop (across the active leaf for a pair of doors), and the door reveal to the door face may be no deeper than 300 mm in any situation (a 2021 addition). The 2021 figures cover swing, cavity sliding, surface-mounted sliding and pivot doors.