Victoria adds VIC B6P8 (a rainwater service must avoid contamination, pose no public health hazard, have no unprotected cross-connection with the drinking supply and keep a continuous supply for sanitary flushing where a reticulated supply is connected, with VIC B6D8 on an automatic or manual interchange device), VIC Part C4 low risk on-site liquid trade waste (C4P1: appliances located close to the fixtures served, fitted with removable covers able to bear loads, built of suitable materials and vented in specified sizes), VIC Part E2 heating, ventilation and air-conditioning (design, construction, installation, maintenance, pressure equipment, microbial control), VIC Part E3 roof drainage and VIC Part E4 surface drainage, varies B1D3, B3D3, B4D2, B5D7 and C2D4, and replaces A2G2 and A5G4 (with its own evidence of suitability for Volume Three). VIC A2G2 keeps the bar on Performance Solutions for combustible cladding in certain Class 2 to 9 buildings (a Volume One matter).