Australia National Construction Code 2025 Volume Three (Plumbing Code of Australia)
Part B2: Heated water services – Australia National Construction Code 2025 Volume Three (Plumbing Code of Australia)

Australia National Construction Code 2025 Volume Three (Plumbing Code of Australia) B2P6: B2P6 Relieve pressure and limit temperature in heated water containers

Containers producing or storing heated water must relieve excess pressure and avoid flash steam by keeping pressure within the lesser of the maximum rated working pressure and 1400 kPa (with a tolerance of 5 per cent or 14 kPa, whichever is greater) and limiting water temperature to 99 degrees Celsius, or by other means giving equal safety. Deemed-to-Satisfy B2D7 requires a temperature and pressure relief device to AS/NZS 3500.4. Verification Method B2V1 checks storage by requiring all water to be held at a temperature for a minimum exposure period within seven days: at least 70 degrees for 1 second, 66 degrees for 2 minutes or 60 degrees for 32 minutes.