AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work
Section 7: Walkways, ramps and landings – AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work

AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work 7.3: 7.3 Ramps

A ramp longer than 1900 mm may be no steeper than 1 in 14 and keeps a constant gradient (predecessor tolerance 3 % provided no part exceeds 1 in 14). Landings are needed top and bottom and at intervals of no more than 9 m at 1 in 14 and 15 m at 1 in 20, interpolated between. Each side carries a handrail to Section 9, handrails at least 1000 mm apart and extending at least 300 mm past the top and bottom transitions unless the inside rail runs unbroken around an intermediate landing. At a property boundary the ramp is set back at least 900 mm keeping handrails and tactile indicators out of the crossing path; at an internal corridor the set-back is at least 400 mm. Where the handrail is not wall-supported, ramps and intermediate landings have kerbs or kerb rails at least 65 mm high with the top kept out of the 75 mm to 150 mm height band and no lengthwise gap wider than 20 mm within that band, located relative to the handrail as the Standard details.

Maintained by Gerard Blokdyk

Other controls in Section 7: Walkways, ramps and landings – AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.