LEED v4.1 - Green Building Rating System (US Green Building Council) EQc3: EQ Credit: Construction Indoor Air Quality Management Plan

What does EQc3 require?

1 point; applies to all eight BD+C adaptations. Implement a construction IAQ plan meeting SMACNA IAQ Guidelines chapter 3, protecting absorptive materials from moisture, running air handlers only with MERV 8 filters on returns and replacing filters before occupancy, and banning smoking within 25 feet of openings; healthcare adds moisture, VOC sequencing, outdoor fumes, noise and vibration (BS 5228) and infection control risk assessment.