1 to 3 points; applies to all eight BD+C adaptations. Meet low-emitting criteria in two (1 point), three (2 points) or four or more product categories (3 points, exemplary with five): paints and coatings, plus adhesives and sealants (75% meeting CDPH v1.2-2017 emissions testing and 100% meeting VOC content limits), flooring and ceilings (90%), wall panels, insulation, furniture (BIFMA e3) and composite wood (ULEF or NAF formaldehyde) at 75%, with inherently non-emitting and salvaged materials accepted where allowed.
The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.