Where the side approach is clear, or blocked by an integral element shallower than 255 mm, one or more operable parts of every type must be between 380 mm and 1 220 mm above the access floor. Where an integral obstruction exists it must be under 865 mm high; with a depth up to 255 mm the high reach is at most 1 220 mm, and with a depth over 255 mm up to 610 mm at most 1 170 mm.