AS 3740:2021 Waterproofing of Domestic Wet Areas
Section 4: Installation - penetrations, baths, shower bases, screens and floor finishes – AS 3740:2021 Waterproofing of Domestic Wet Areas

AS 3740:2021 Waterproofing of Domestic Wet Areas 4.12.1: 4.12.1 Penetrations in shower areas

Penetrations for taps, shower outlets, recessed soap holders and similar are waterproofed with preformed flange systems or sealant, allowing tap washers or ceramic discs to be serviced without damaging the seal. Any fixing or fastener penetrating surface materials must also be waterproofed. Notes cover ceiling roses, mixer tap cover plate drainage and mixers that cannot be integrated with the membrane (outside the Standard).

Maintained by Gerard Blokdyk

Other controls in Section 4: Installation - penetrations, baths, shower bases, screens and floor finishes – AS 3740:2021 Waterproofing of Domestic Wet Areas

Query this from an agent

The graph holds this control, the 0 it maps to, and the evidence behind each claim, over MCP and REST.