AS 1684.2:2021 Residential Timber-Framed Construction - Non-Cyclonic Areas
Section 6: Wall framing – AS 1684.2:2021 Residential Timber-Framed Construction - Non-Cyclonic Areas

AS 1684.2:2021 Residential Timber-Framed Construction - Non-Cyclonic Areas 6.2.2: 6.2.2 Plates

Top plates are continuous along every wall, openings included; bottom plates run full length except at doors, butt-jointed only with both ends supported; bottom plates under jamb studs of wide openings or under concentrated loads are stiffened; top plates under concentrations of load between studs are stiffened or blocked as the figure shows (metal connectors or double blocking for larger roof areas); top plates and ring beams are joined as Section 9 specifies.