AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work 3.3: 3.3 Width of the continuous accessible path

Unless another clause sets a different figure (doors, curved ramps and similar), the path's clear width is at least 1000 mm, and nothing may intrude into it: fixtures such as lights, awnings, open windows, telephones and skirtings; essential items such as fire hose reels and extinguishers; or door handles lower than 900 mm above the floor.