AS/NZS 3500.1:2021 Plumbing and Drainage - Water Services
Section 5: Installation of cold water services – AS/NZS 3500.1:2021 Plumbing and Drainage - Water Services

AS/NZS 3500.1:2021 Plumbing and Drainage - Water Services 5.11: 5.11 Bedding and backfill

Buried pipes are surrounded by compacted sand or fine-grained soil (75 mm in the 2003 text) with nothing hard touching the pipe; excavated material may be used for final backfill only if free of rock, hard and organic matter and large lumps.