AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work
Sections 11 to 15: Controls, sanitary facilities, grabrails and assembly seating – AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work

AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work 14: Section 14 Grabrails

In the predecessor, grabrails are 30 mm to 40 mm outside diameter or an equivalent section, have exposed edges and corners of at least 5 mm radius, withstand 1100 N applied anywhere in any direction without deforming, loosening or rotating, clear the wall by 50 mm to 60 mm with 600 mm clear above horizontal rails and at least 50 mm below horizontal or angled rails except at fixings, and leave the top 270 degree arc free for the hand (full length for vertical rails).