AS 1428.1:2021 Design for Access and Mobility - General Requirements for Access, New Building Work 11: Section 11 Switches and general purpose outlets

In the predecessor, switches and controls on the accessible path (other than power outlets) are 900 mm to 1100 mm above floor and at least 500 mm from internal corners unless on the latch-side architrave; in accessible sole-occupancy units and sanitary facilities, rocker or toggle switches are at least 30 mm by 30 mm (push pads also have a minimum size), and power outlets are 600 mm to 1100 mm above floor and at least 500 mm from internal corners.